GENERAL DESCRIPTION

The R-C Snubber is intended to suppress the "inductive kick" from motors, solenoids or relay coils. High energy noise spikes are generated whenever current is interrupted through an inductive load. These noise spikes may interfere with associated equipment causing erratic operation and may also accelerate relay contact wear. Applied across an inductive load, the R-C snubber suppresses the noise spikes and extends contact life.


Ordering Information:
Model No.
Description
Part Number
SNUB
R-C Snubber Inductive Load Suppressor
SNUB0000

UL recognized component
(Okaya Electric America, Inc. PN#XEB0471, UL-1414, File # E47474)


APPLICATION

The R-C snubber inductive load suppressor should be applied as shown below. Placing the suppressor across the contact in many cases can work as well, but for maximum effect, it is best to place the suppressor directly across the load. All inductive loads in a system should be suppressed in this manner to avoid mutual interference; the suppressors are effective with both AC and DC circuits.

 

 