Manufacturer: Asco LP
Mfg Product Code: 8030G069AC110/60D
Weight: 2.43 lb(s)
Gas Vent Sol Valve, 1/2" NPT, 110 VAC, 2 Way-2/2 NC
The ASCO Series 030, also known as 8030, is a direct-acting low-pressure solenoid valve with up to 15 psi (1 Bar) maximum differential. Valves available in brass or stainless steel, normally open or normally closed and pipe sizes 3/8-inch thru 3/4. They are widely used for dispensing, collating, vacuum holding, tank draining and gas shutoff applications. The normally open version is well suited for gas venting.
Features
- Body Material: Brass
- Flow (Cv): 2.80
- Valve Function: 2 Way - 2/2 Normally Closed
- Pipe/Port Type & Size: NPT 1/2
- Valve Actuation: Solenoid: Direct Acting
- Voltage & Frequency: 110 AC with 60 Hz
- Product Weight: 2.43 lbs
- Kit Number: 306629
- Coil Class: FT
- Coil Number: 238610-027-D
- Min to Max Ambient Temperature: 32 - 125 deg;F
- Min to Max Fluid Temperature: 32 - 125 °F
- Orifice Size: 7/16 in
- Watt Rating: 10.1 W
- Item Status: Active
- Lead Length: 18 inch
- Carton Note: 1/2 X 7/16 2NC BRASS 10.1/F AC
- Holding Current (VA): 25
- Seating Elastomer: NBR
- Mounting Direction: ANY:
This product is no longer available.
030 Series Gas Vent Solenoid Valve (8030), 1/2" NPT, 110 VAC, Brass, 2 Way-2/2 NC
This product is no longer available.
Gas Vent Sol Valve, 1/2" NPT, 110 VAC, 2 Way-2/2 NC
Actuation:Solenoid - Direct Acting
Brand:Asco
Manufacturer Product Family:030 Series
Orifice Size:7/16 in
Mounting Direction:Any
Process Connection Type:NPT
Flow Coefficient:2.80 Cv
Max Operating Temperature:125 °F
Process Connection Size:1/2"
Holding Current (VA):25
Input Voltage:110 VAC
Watts:10.1
Function:2 Way 2/2 Normally Closed
Coil Class:FT
Frequency:60 Hz
Body Material:Brass
Lead Length:18 in
NEMA / UL:NEMA 1/2/3/3S/4/4X
Seating Elastomer:NBR
Seal Material:NBR
Specifications
Valve Features | |
---|---|
Actuation | Solenoid - Direct Acting |
Uncategorized | |
---|---|
Brand | Asco |
Manufacturer Product Family | 030 Series |
Orifice Size | 7/16 in |
Mounting Direction | Any |
Process Connection Type | NPT |
Flow Coefficient | 2.80 Cv |
Max Operating Temperature | 125 °F |
Process Connection Size | 1/2" |
Holding Current (VA) | 25 |
Input Voltage | 110 VAC |
Watts | 10.1 |
Function | 2 Way 2/2 Normally Closed |
Coil Class | FT |
Frequency | 60 Hz |
Body Material | Brass |
Lead Length | 18 in |
NEMA / UL | NEMA 1/2/3/3S/4/4X |
Seating Elastomer | NBR |
Seal Material | NBR |