Representative photo. Please check item description for details.

11 Series Sanitary Clamp Pressure Transmitter, 0 psig to 300 psig

  • Product Unit of Measure
  • Process Connection Size
  • Measurement Maximum
  • Process Connection Type
  • Pressure Range
  • Accuracy
  • Case Material
  • Min Operating Pressure
  • Max Operating Pressure
  • Min Operating Temperature
  • Max Operating Temperature
  • Wetted Material
  • Output Communication Protocol
  • Input Voltage
  • Ingress Protection
  • Response Time
  • Fill Liquid
  • Electrical Connector Type

1,156.99 1,156.99 1156.99 USD

1,156.99

This combination does not exist.

Add to Cart

Manufacturer: Noshok Inc

Mfg Product Code: 110-16-4-615-1-61-1-1

Weight: 1.1 lb(s)

On Hand: 0

2" Sanitary Clamp, ±0.25% Accy BFSL, 0-300 psig, 4-20 mA O/P Sanitary Transducer, DIN EN 175301-803 Form A (36" Cable Att.)

  • Series 615 transducer
  • Current and voltage outputs available
  • 316 Stainless Steel wetted parts
  • Can be cleaned-in-place (CIP) or steamed-in-place (SIP)
  • 3A Certified
  • CE compliant to suppress RFI, EMI and ESD

Applications:

  • Food & beverage processing
  • Pasteurization systems
  • Pharmaceutical
  • Medical

WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov


Product Unit of Measure: psig
Process Connection Size: 2"
Measurement Maximum: 300.0
Process Connection Type: Clamp
Pressure Range: 0 psig to 300 psig
Accuracy: ±0.25% full scale (BFSL)
Case Material: 316 SS
Min Operating Pressure: 0 psig
Max Operating Pressure: 300 psig
Min Operating Temperature: -40 °F
Max Operating Temperature: 300 °F
Wetted Material: 316 SS
Output Communication Protocol: 4-20 mA
Input Voltage: 10-30VDC
Ingress Protection: IP65
Response Time: ≤10 ms
Fill Liquid: FFL767 White Oil
Electrical Connector Type: DIN EN 175301-803 Form A


Product Datasheets

Datasheet 1


Specifications for 11 Series Sanitary Clamp Pressure Transmitter, 0 psig to 300 psig

Product Unit of Measure psig
Process Connection Size 2"
Measurement Maximum 300.0
Process Connection Type Clamp
Pressure Range 0 psig to 300 psig
Accuracy ±0.25% full scale (BFSL)
Case Material 316 SS
Min Operating Pressure 0 psig
Max Operating Pressure 300 psig
Min Operating Temperature -40 °F
Max Operating Temperature 300 °F
Wetted Material 316 SS
Output Communication Protocol 4-20 mA
Input Voltage 10-30VDC
Ingress Protection IP65
Response Time ≤10 ms
Fill Liquid FFL767 White Oil
Electrical Connector Type DIN EN 175301-803 Form A