Representative photo. Please check item description for details.

Safety Relay Module for Safety Mats, SM-GA-5A

https://www.branom.com/web/image/product.template/33142/image_1920?unique=c49b750
(0 review)

Manufacturer: Banner Engineering Corp

Mfg Product Code: 66093

Weight: 1.26 lb(s)

On Hand: 0

Safety Relay Module for Safety Mats

Features:

  • Safety Relay Module for Safety Mats
  • Supply Voltage: 115 V ac or 12 to 24 V dc
  • Safety Input: 4-Wire Safety Mat
  • Safety Output: 4 NO, 6 Amp
  • Aux Output: 1 NC, 5 Amp and 2 Solid State, 100 mA
  • Terminal Block: Removable
  • Width: 45mm
  • Self-Checking Circuitry, Auto/Manual Reset, EDM

447.00 447.0 USD 447.00

447.00

Not Available For Sale

  • Measurement Maximum
  • Max Operating Temperature
  • Power Consumption
  • Measurement Minimum
  • Ingress Protection
  • Device Type
  • Feature: PCCC
  • Feature: Has EtherNet/IP
  • Feature: Modbus/TCP
  • Supply Voltage
  • Safety Module Type
  • Independently Controlled Safe Outputs
  • PL Rating
  • Non Safe Output Rating
  • SISTEMA
  • Relative Humidity
  • Vibration
  • Feature: LCD Display
  • SIL Rating
  • Safety Category Rating
  • Input Configuration
  • Terminal Type
  • Input Operation
  • Number of Safe Inputs
  • Safety Input - Reset
  • Safety Mat
  • Input Resistance
  • Recovery Time
  • Response Time
  • Non Safe Output Configuration
  • Number of Stored Colors
  • Country of Origin
  • Feature: Common Ethernet Protocol
  • Electrical Life
  • Feature: E-Stops/Rope Pulls
  • Feature: Expandable
  • Feature: Removable Terminals
  • Feature: Gate Switch (NC/NC) Input
  • Feature: Gate Switch (NC/NO) Input
  • Feature: Gate Switch (OSSD) Input
  • Feature: Light Curtains/Scanner with EDM Input
  • Feature: Light Curtains/Scanner without EDM Input
  • Feature: Motor Speed
  • Feature: Muting
  • Safety Input - Dual Channel (Dry Contact)
  • Feature: Safety Mat
  • Feature: In-Series Diagnostics
  • Mechanical Life

This combination does not exist.

Safety Relay Module for Safety Mats, SM-GA-5A

  • Measurement Maximum
  • Max Operating Temperature
  • Power Consumption
  • Measurement Minimum
  • Ingress Protection
  • Device Type
  • Feature: PCCC
  • Feature: Has EtherNet/IP
  • Feature: Modbus/TCP
  • Supply Voltage
  • Safety Module Type
  • Independently Controlled Safe Outputs
  • PL Rating
  • Non Safe Output Rating
  • SISTEMA
  • Relative Humidity
  • Vibration
  • Feature: LCD Display
  • SIL Rating
  • Safety Category Rating
  • Input Configuration
  • Terminal Type
  • Input Operation
  • Number of Safe Inputs
  • Safety Input - Reset
  • Safety Mat
  • Input Resistance
  • Recovery Time
  • Response Time
  • Non Safe Output Configuration
  • Number of Stored Colors
  • Country of Origin
  • Feature: Common Ethernet Protocol
  • Electrical Life
  • Feature: E-Stops/Rope Pulls
  • Feature: Expandable
  • Feature: Removable Terminals
  • Feature: Gate Switch (NC/NC) Input
  • Feature: Gate Switch (NC/NO) Input
  • Feature: Gate Switch (OSSD) Input
  • Feature: Light Curtains/Scanner with EDM Input
  • Feature: Light Curtains/Scanner without EDM Input
  • Feature: Motor Speed
  • Feature: Muting
  • Safety Input - Dual Channel (Dry Contact)
  • Feature: Safety Mat
  • Feature: In-Series Diagnostics
  • Mechanical Life

447.00 447.0 USD 447.00

447.00

Not Available For Sale

This combination does not exist.


Safety Relay Module for Safety Mats


Measurement Maximum:0
Max Operating Temperature:50 °C
Power Consumption:4 W / 7 VA
Measurement Minimum:0
Ingress Protection:IP20
Device Type:Safety Relay
Feature: PCCC:No
Feature: Has EtherNet/IP:No
Feature: Modbus/TCP:No
Supply Voltage:115 VAC; 12-24 VDC
Safety Module Type:Safety Mat Module
Independently Controlled Safe Outputs:1
PL Rating:e
Non Safe Output Rating:Relay - 5 A
SISTEMA:PFHd = 5.8 x 10-8
Relative Humidity:90% @ 50 °C
Vibration:10-60 Hz at 0.35 mm
Feature: LCD Display:No
SIL Rating:3
Safety Category Rating:4
Input Configuration:2 NC
Terminal Type:Screw
Input Operation:4-Wire
Number of Safe Inputs:1
Safety Input - Reset:20-50 mA @ 12-30 VDC
Safety Mat:Yes
Input Resistance:250 Ω max. per channel
Recovery Time:350 ms
Response Time:≤35 ms
Non Safe Output Configuration:1 NC, 2 PNP
Number of Stored Colors:1
Country of Origin:US
Feature: Common Ethernet Protocol:No
Electrical Life:150,000 @ 1500 VA
Feature: E-Stops/Rope Pulls:No
Feature: Expandable:No
Feature: Removable Terminals:Yes
Feature: Gate Switch (NC/NC) Input:No
Feature: Gate Switch (NC/NO) Input:No
Feature: Gate Switch (OSSD) Input:No
Feature: Light Curtains/Scanner with EDM Input:No
Feature: Light Curtains/Scanner without EDM Input:No
Feature: Motor Speed:No
Feature: Muting:No
Safety Input - Dual Channel (Dry Contact):20-100 mA @ 12-30 VDC
Feature: Safety Mat:Yes
Feature: In-Series Diagnostics:No
Mechanical Life:20 mil


Specifications

Measurement Maximum 0
Max Operating Temperature 50 °C
Power Consumption 4 W / 7 VA
Measurement Minimum 0
Ingress Protection IP20
Device Type Safety Relay
Feature: PCCC No
Feature: Has EtherNet/IP No
Feature: Modbus/TCP No
Supply Voltage 115 VAC; 12-24 VDC
Safety Module Type Safety Mat Module
Independently Controlled Safe Outputs 1
PL Rating e
Non Safe Output Rating Relay - 5 A
SISTEMA PFHd = 5.8 x 10-8
Relative Humidity 90% @ 50 °C
Vibration 10-60 Hz at 0.35 mm
Feature: LCD Display No
SIL Rating 3
Safety Category Rating 4
Input Configuration 2 NC
Terminal Type Screw
Input Operation 4-Wire
Number of Safe Inputs 1
Safety Input - Reset 20-50 mA @ 12-30 VDC
Safety Mat Yes
Input Resistance 250 Ω max. per channel
Recovery Time 350 ms
Response Time ≤35 ms
Non Safe Output Configuration 1 NC, 2 PNP
Number of Stored Colors 1
Country of Origin US
Feature: Common Ethernet Protocol No
Electrical Life 150,000 @ 1500 VA
Feature: E-Stops/Rope Pulls No
Feature: Expandable No
Feature: Removable Terminals Yes
Feature: Gate Switch (NC/NC) Input No
Feature: Gate Switch (NC/NO) Input No
Feature: Gate Switch (OSSD) Input No
Feature: Light Curtains/Scanner with EDM Input No
Feature: Light Curtains/Scanner without EDM Input No
Feature: Motor Speed No
Feature: Muting No
Safety Input - Dual Channel (Dry Contact) 20-100 mA @ 12-30 VDC
Feature: Safety Mat Yes
Feature: In-Series Diagnostics No
Mechanical Life 20 mil