Representative photo. Please check item description for details.
14" Krohne Optiflux 4000 Flow Sensor
Manufacturer: Krohne Inc
Mfg Product Code: VN044H
On Hand: 0
Electromagnetic Flow Sensor
- Robust, fully welded construction for industrial process applications
- For demanding applications including corrosive, abrasive and high pressure
- Engineered constructions for customer specific solutions
Highlights
- Trusted and accepted flow sensor for all process applications
- Proven in use and unsurpassed lifetime
- Large installed base – more than 400.000 units - in virtually any industry
- All welded rugged construction, to extend lifetime of equipment
- Good corrosion, erosion / abrasion resistance
- Wide choice of materials for housing and flanges including SS, Duplex, 6Mo
- Flexibility in sizes including installation lengths, special constructions, special inner diameters and liner thicknesses
- Corrosion resistant and leak tight electrodes. Specials (materials, retractable or pointed) on demand
- External coatings for offshore or subsoil installation. Optional paint specifications according to ISO 12944 – protective coating
- Reliable measurement under very demanding conditions: including high temperatures up to 180°C / 356°F, pressures up to 1500 bar / 21755 psi, high solids contents (up to 70%)
- Bi-directional flow metering
- Wide range of approvals for hazardous areas
- Compliant with requirements for custody transfer OIML R49 & R117, MI-001, MI-004 & MI-005
- No grounding rings with virtual reference option on IFC 300
- Extensive diagnostic capabilities
- Suitable for SIL 2/3 safety applications in combination with IFC 400
14" Krohne Optiflux 4000 Flow Sensor
Specifications
Optiflux/Waterflux | |
---|---|
System Design | [1] Compact/Integral Transmitter (Aluminum Housing) or [2] Compact/Integral Transmitter (Stainless Steel Housing) or [4] Separate/Remote Transmitter (Aluminum Junction Box) or [A] Separate/Remote Transmitter (Stainless Steel Junction Box) *Required for IP68 |
Converter Model (Purchased Separately) | [3] IFC 100 C (Compact) or [4] IFC 100 W (Wall Mount) or [C] IFC 300 C (Compact) or [D] IFC 300 F (Field Mount) or [E] IFC 300 W (Wall Mount) or [F] IFC 300 R (Rack Mount) or [K] IFC 050 C (Compact) or [L] IFC 050 W (Wall Mount) or [0] Without - Replacement Flow Tube |
Electrodes | [B1] Hastelloy C22 or [11] 316 Ti SS or [31] Hastelloy C4 or [41] Hastelloy B or [51] Tantalum or [61] Titanium or [71] Platinum or [H1] Conductive Rubber or [K1] Tungsten Carbide Coated-Hastelloy C22 Base Low Noise or [V1] Tungsten Carbide Coated-316 SS Base Low Noise |
Protection Category | [0] IP 66/67 acc. To NEMA 4/4X/6 or [2] IP 68 acc. to NEMA 6P (Rated for Submergence) *SS Junction Box Required |
Cable Length | [00] Compact - None or [00] 15 ft. DS Signal Cable or [01] 30 ft. DS Signal Cable or [02] 45 ft. DS Signal Cable or [03] 60 ft. DS Signal Cable or [04] 75 ft. DS Signal Cable or [05] 90 ft. DS Signal Cable or [06] 120 ft. DS Signal Cable or [07] 150 ft. DS Signal Cable or [08] 300 ft. DS Signal Cable or [00] 15 ft. DS Signal and Coil Power Cables or [01] 30 ft. DS Signal and Coil Power Cables or [02] 45 ft. DS Signal and Coil Power Cables or [03] 60 ft. DS Signal and Coil Power Cables or [04] 75 ft. DS Signal and Coil Power Cables or [05] 90 ft. DS Signal and Coil Power Cables or [06] 120 ft. DS Signal and Coil Power Cables or [07] 150 ft. DS Signal and Coil Power Cables or [08] 300 ft. DS Signal and Coil Power Cables |
Optiflux/Waterflux-14" | |
---|---|
Process Connections | [A] ASME 150lb RF Flanges or [B] ASME 300lb RF Flanges |
Housing/Flange Material | [1] Sheet Steel/Carbon Steel (150 lb) or [1] Sheet Steel/Carbon Steel (300 lb) or [3] Sheet Steel/316L Stainless Steel (150 lb) or [3] Sheet Steel/316L Stainless Steel (300 lb) |
Optiflux-14" | |
---|---|
Grounding Rings | [6] (2) Ring #1 / Stainless Steel (150 lb) or [6] (2) Ring #1 / Stainless Steel (300 lb) or [7] (2) Ring #1 / Hastelloy C or [5] (2) Ring #1 / Titanium or [4] (2) Ring #1 / Tantalum or [P] (2) Protection Ring #2 / Stainless Steel(150 lb) or [P] (2) Protection Ring #2 / Stainless Steel(300 lb) or [R] (2) Protection Ring #2 / Hastelloy C22 or [N] (2) Protection Ring #2 / Titanium or [0] Without |
Optiflux 4000 | |
---|---|
Hazardous Area Approvals | [0] None / General Purpose or [5] FM Class I DIV 2 or [A] cCSAus OL*Canada Only or [C] CSA Class I DIV 2 *Canada Only |
Calibration | [0] Standard or [2] Standard + 316L SS tagplate (120x46mm), Add Tag # or [3] Standard + 316L SS tagplate (67x25mm), Add Tag # or [A] Custody Transfer or [C] CT+ 316L tagplate (120x46mm), Add Tag # or [D] CT+ 316L tagplate (67x25mm), Add Tag # or [R] Extended Calibration or [S] EC + 316L tagplate (120x46mm), Add Tag # or [T] EC + 316L tagplate (67x25mm), Add Tag # |
Optiflux 4000-14" | |
---|---|
Lining | [0] Tefzel (ETFE) or [2] Teflon (PTFE) or [A] Softrubber - 4mm thick or [P] Softrubber - 6mm thick or [D] Polyurethane - 6mm thick |
Finish | [00000000000] Standard or [30000000000] Offshore |