Skip to Content
Representative photo. Please check item description for details.

Wika IS-3, Hazardous Pressure Transmitter, M12X1 Connector

https://www.branom.com/web/image/product.template/189638/image_1920?unique=c1b9893
(0 review)

Features:

  • S-3 Standard ; 0 ... 3000 psi; 4...20 mA, 2-wire
  • @ 10...30 V DC; Accuracy: 0.25% B.F.S.L.
  • 1/4 NPT
  • Sealing: without
  • Material of Wetted Parts: stainless steel
  • Adjustability: Zero/span adjustable
  • circular connector M12x1 acc. to IEC 61076-2-101 4-pin
  • Cable material: without
  • Cable length: without
  • UB=1, 0V=3
  • permitted media temperature: -20...+80°C
  • Approvals: ATEX/IECEx/FM/CSA
  • II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb, II 1/2D Ex ia IIIC T135 °C Da/Db
  • Additional certifications: without
  • Special features: without
  • Test protocol: without test protocol
  • Additional ordering information: thin-film sensor out of Elgiloy VA2.4711
  • Attention: long term stability per year for hydrogen applications within media temperature range -
  • 40…+30°C +/- 1% typ; +/- 3% max.
  • For higher media temperatures there is no statement possible regarding the long term stability
  • Observe also WIKA Technical Information IN 00.40.
  • Specifications according to data sheet: PE 81.58
  • Customs tariff number: 9026204000

798.21 798.21 USD 798.21

798.21

Not Available For Sale

  • Measurement Maximum
  • Measurement Minimum

This combination does not exist.


Product Datasheets

Datasheet 1

Features:

  • S-3 Standard ; 0 ... 3000 psi; 4...20 mA, 2-wire
  • @ 10...30 V DC; Accuracy: 0.25% B.F.S.L.
  • 1/4 NPT
  • Sealing: without
  • Material of Wetted Parts: stainless steel
  • Adjustability: Zero/span adjustable
  • circular connector M12x1 acc. to IEC 61076-2-101 4-pin
  • Cable material: without
  • Cable length: without
  • UB=1, 0V=3
  • permitted media temperature: -20...+80°C
  • Approvals: ATEX/IECEx/FM/CSA
  • II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb, II 1/2D Ex ia IIIC T135 °C Da/Db
  • Additional certifications: without
  • Special features: without
  • Test protocol: without test protocol
  • Additional ordering information: thin-film sensor out of Elgiloy VA2.4711
  • Attention: long term stability per year for hydrogen applications within media temperature range -
  • 40…+30°C +/- 1% typ; +/- 3% max.
  • For higher media temperatures there is no statement possible regarding the long term stability
  • Observe also WIKA Technical Information IN 00.40.
  • Specifications according to data sheet: PE 81.58
  • Customs tariff number: 9026204000

Specifications

Measurement Maximum 3000.0
Measurement Minimum 0