Representative photo. Please check item description for details.
KROHNE Enviromag 2000 Water/Wastewater Electromagnetic Flow Sensor
The ENVIROMAG 2000 is an electromagnetic flowmeter. The magmeter is the optimum solution for North American water and wastewater measurement applications. Its design and performance makes it the instrument of choice for flow measurement throughout the process.
The ENVIROMAG 2000 is an electromagnetic flowmeter. The magmeter is the optimum solution for North American water and wastewater measurement applications. Its design and performance makes it the instrument of choice for flow measurement throughout the process.
Specifications
| Flow Sensor Tube | [VB16] Krohne Standard, [SB16] Krohne Special |
| Customization | [4] Krohne Standard, [9] Customer Specified |
| Nominal Diameter | [P] DN700 | 28", [Y] DN750 | 30", [R] DN800 | 32", [S] DN900 | 36", [T] DN1000 | 40", [W] DN1050 | 42", [U] DN1200 | 48", [X] DN1350 | 54", [V] DN1400 | 56", [Z] DN1500 | 60" |
| Nominal Pressure | [A] 150 lb RF ASME B 16.5, [X] AWWA C207 Class B, [W] AWWA C207 Class D |
| Ex Approval | [0] without, [A] CSA Ordinary Location |
| Design | [0] Compact Converter with Aluminum Housing, [2] Compact Converter with Stainless Steel Housing, [4] Remote Converter with Aluminum Junction Box - 1/2" NPT, [A] Remote Converter with Stainless Steel Junction Box - 1/2" NPT |
| Converter Model | [3] IFC 100 C - Compact Mount, [4] IFC 100 W - Wall Mount, [C] IFC 300 C - Compact Mount, [D] IFC 300 F - Field Mount, [E] IFC 300 W - Wall Mount, [F] IFC 300 R - Rack Mount, [K] IFC 050 C - Compact Mount, [L] IFC 050 W - Wall Mount |
| Lining | [0] Hard Rubber, [D] Polyurethane |
| Electrodes | [B] Hastelloy C22, [2] Stainless Steel 1.4401|316, [4] Hastelloy B2, [5] Tantalum, [6] Titanium, [7] Platinum |
| Electrode Construction | [2] Exchangeable, [2] non-Exchangeable |
| Housing / Flange Material | [1] Sheet Steel / Carbon Steel, [2] Sheet Steel / Stainless Steel 1.4306|304L, [3] Sheet Steel / Stainless Steel 1.4404|316L |
| Protection Class | [0] IP66/67, [2] IP68 |
| Signal Cable | [0] none - Compact Converter, [0] DS - Double Shielded, [1] BTS - Triple Shielded |
| Cable Length | [0] none - Compact Converter, [0] 15ft Signal Cable, [1] 30ft Signal Cable, [2] 45ft Signal Cable, [3] 60ft Signal Cable, [4] 75ft Signal Cable, [5] 90ft Signal Cable, [6] 120ft Signal Cable, [7] 150ft Signal Cable, [8] 300ft Signal Cable, [0] 15ft Signal Cable + Coil Power Cable, [1] 30ft Signal Cable + Coil Power Cable, [2] 45ft Signal Cable + Coil Power Cable, [3] 60ft Signal Cable + Coil Power Cable, [4] 75ft Signal Cable + Coil Power Cable, [5] 90ft Signal Cable + Coil Power Cable, [6] 120ft Signal Cable + Coil Power Cable, [7] 50ft Signal Cable + Coil Power Cable, [8] 300ft Signal Cable + Coil Power Cable |
| Calibration | [0] 2-Point Calibration, [1] 2-Point Calibration w/ 304 SS Tagplate (67 x 25mm), [2] 2-Point Calibration w/ 316 SS Tagplate (120 x 46mm), [3] 2-Point Calibration w/ 316 SS Tagplate (67 x 25mm) |
| Grounding Ring (x2) | [0] without, [6] Grounding Ring #1 / Stainless Steel 1.4404|316L, [2] Grounding Ring #1 / Hastelloy C4, [E] Insertion Ring #3 / Stainless Steel 1.4404|316L |
| Finish | [0] Standard |
| Markings | [0] Krohne Blue |
| Construction Requirements | [0] Standard |
| QA/QC Requirements | [0] Standard |
| Extended Nominal Diameter | [0] without |
| Ratio of CT-Calibration | [0] Standard |
| Instruction Language | [0] English |
| Tag Plate | [0] Standard |
| Destination | [0] Standard |
| Flange Material | [0] Standard |
| Reserve Option | [0] without |