Skip to Content
Representative photo. Please check item description for details.

KROHNE IFC 300 Electromagnetic Flow Signal Converter

https://www.branom.com/web/image/product.template/182957/image_1920?unique=aa7f2be
(0 review)

Code Prefix: VN304

  • Type
  • Power Supply
  • Hazardous Area Approvals
  • Cable Connection
  • Custody Transfer
  • Process Diagnostics
  • Converter Housing
  • Outputs - Communication
  • First IO Module
  • Second IO Module
  • Reference Method
  • Tag Plate

This combination does not exist.


Product Datasheets

Datasheet 1

Description

Signal converter for electromagnetic flowmeters

  • All-round signal converter matches almost any application requirement
  • Reliable measurements with extensive diagnostics of device and application
  • Wide range of communication options including PROFINET

Highlights

  • For operation with complete OPTIFLUX, WATERFLUX and OPTIPROBE flow sensor line
  • For flow sensors over a diameter range of DN2.5...3000/ 1/10…120"
  • Continuous measurement of volume flow and flow velocity Integrated conductivity measurement, mass flow (at constant density) and coil temperature
  • High measuring accuracy and long-term stability: ±0.15% of measured value ± 1mm/s
  • Optimal zero point stability independent from product properties
  • Power supply via 100…230VAC (standard) or 24VDC or 24VAC/DC (optional)
  • Superior process reliability thanks to standard integrated diagnostics: testing of device functions, check for compliance with specifications and application testing
  • Available inputs and outputs: Current output (including HART®), pulse/frequency output, status output, control input and current input
  • Communication interfaces for integration into third party systems via HART® (as standard), Modbus, FOUNDATION™ Fieldbus, PROFIBUS® and PROFINET IO
  • Wide range of custody transfer approvals including OIMLR49-1 and R117-1, MI-001, MI-004 and MI-005

Specifications

Type C - Compact, W - Wall Mount, F - Field Mount, C / CAP - Compact (OPTIFLUX 7000 only), F / PF - Field Mount (TIDALFLUX 2000 only), RL - Rack Light
Power Supply 85-250 VAC, 12-24 VDC, 19-29 VDC/AC, 12-24 VDC ***Only for Profinet, includes 1xM12 (PS) connector, 85-250 VAC ***Only for Profinet
Hazardous Area Approvals None / General Purpose, FM Class I DIV 2, Class I DIV 1, cCSAus OL, CSA Class I DIV 2
Cable Connection 1/2" NPT, 1 x M12, connector, 2 x M12, connectors, M20 x 1,5, Strip: tag, 1/2" NPT incl. Physical Manual, 1 x M12, connector incl. Physical Manual, 2 x M12, connectors incl. Physical Manual, M20 x 1,5 incl. Physical Manual, Strip: tag incl. Physical Manual
Custody Transfer Without, Water, NMi OIML R49 *Q3 = fixed per size, R = 80: Other Q3 & R Values available on request, Other than water, OIML R117 *Q3 = fixed per size, R = 80: Other Q3 & R Values available on request
Process Diagnostics Standard, Batchcontrolling
Converter Housing Die-Cast Aluminum (Polyurethane Coated), Polyamide-Polycarbonate - W, Die-Cast Aluminum (Polyurethane Coated) - F / PF, 316 Stainless Steel - C, 316 Stainless Steel - F, Die-Cast Aluminum (Polyurethane Coated), Sealed for Custody Transfer, 316 Stainless Steel, Sealed for Custody Transfer - C, 316 Stainless Steel, Sealed for Custody Transfer - F, Polyamide, Sealed for Custody Transfer - W, Die-Cast Aluminum (Polyurethane Coated) w/ Plastic Window, 316 Stainless Steel w/ Plastic Window - C, 316 Stainless Steel w/ Plastic Window - F
Outputs - Communication 4-20 mA/HART + Pulse/Frequency + Status + Control *Standard, Ex-i IO (current output active + pulse output passive), Ex-i IO (current output passive + pulse output passive), Current active + Pulse active, Current active + Pulse passive, Current active + Pulse Namur, Current passive + Pulse active, Current passive + Pulse passive, Current passive + Pulse Namur, Fieldbus IO: Profibus PA, Fieldbus IO: Foundation Fieldbus, Fieldbus IO: Profibus DP, IO: RS485 Modbus, Ethernet: Profinet
First IO Module No module possible, Ex-i IO (current output active + pulse output passive), Ex-i IO (current output passive + pulse output passive), Without IO module, Current active, Current passive, Pulse active/high current, Pulse passive/high current, Pulse passive/Namur, Control Input active/high current, Control Input active/Namur, Control Input passive/high current
Second IO Module No module possible, Without IO module, Current active, Current passive, Pulse active/high current, Pulse passive/high current, Pulse passive/Namur, Control Input active/high current, Control Input active/Namur, Control Input passive/high current
Reference Method Standard, Virtual Reference
Tag Plate Without, 316SS (120x46mm), 316SS (67x25mm)