Skip to Content
Representative photo. Please check item description for details.

KROHNE Optiflux 2000 Water/Wastewater Electromagnetic Flow Sensor - [VN164]

https://www.branom.com/web/image/product.template/560361/image_1920?unique=c1b9893
(0 review)

Electromagnetic Flow Sensor

  • For all water and wastewater applications
  • Wide range of approvals for potable water
  • Robust, fully welded construction with full bore pipe

Features

  • Rugged liners suitable for any water and wastewater application
  • Proven and unsurpassed lifetime, huge installed base
  • Tamper proof, fully welded construction, also available in customer specific constructions
  • Drinking water approvals including KTW, KIWA, DVGW, ACS, NSF, WRAS
  • Suitable for subsoil installation and constant flooding (IP68)
  • Bi-directional flow metering
  • Compliant with requirements for custody transfer (MID MI-001, OIML R49, ISO 4064, EN 14154)
  • Standard in house wet calibration of flow sensors up to diameter DN3000
  • Easy installation and commissioning
  • No grounding rings with virtual reference option on IFC 300
  • In-situ verification with OPTICHECK
  • Extensive diagnostic capabilities
  • Maintenance-free

  • Nominal Diameter
  • Nominal Pressure
  • Ex-Approval
  • Design / Cable Connection
  • Converter Model
  • Lining
  • Electrodes
  • Construction of Electrodes
  • Housing / Flange Material
  • Protection Class
  • Cable
  • Cable Length
  • Calibration
  • Grounding Rings (x2)
  • Finish
  • Markings
  • Construction Requirements
  • QA/QC Requirements
  • Extended Nominal Diameter
  • Ratio of CT-Calibration
  • Instruction Language
  • Tag Plate
  • Destination
  • Flange Material
  • Reserve Option

This combination does not exist.


Product Datasheets

Datasheet 1

Electromagnetic Flow Sensor

  • For all water and wastewater applications
  • Wide range of approvals for potable water
  • Robust, fully welded construction with full bore pipe

Features

  • Rugged liners suitable for any water and wastewater application
  • Proven and unsurpassed lifetime, huge installed base
  • Tamper proof, fully welded construction, also available in customer specific constructions
  • Drinking water approvals including KTW, KIWA, DVGW, ACS, NSF, WRAS
  • Suitable for subsoil installation and constant flooding (IP68)
  • Bi-directional flow metering
  • Compliant with requirements for custody transfer (MID MI-001, OIML R49, ISO 4064, EN 14154)
  • Standard in house wet calibration of flow sensors up to diameter DN3000
  • Easy installation and commissioning
  • No grounding rings with virtual reference option on IFC 300
  • In-situ verification with OPTICHECK
  • Extensive diagnostic capabilities
  • Maintenance-free

Specifications

Nominal Diameter [P] DN700 | 28", [P] DN750 | 30", [R] DN800 | 32", [R] DN850 | 34", [S] DN900 | 36", [S] DN950 | 38", [T] DN1000 | 40", [T] DN1050 | 42", [T] DN1100 | 44", [T] DN1150 | 46", [U] DN1200 | 48", [U] DN1250 | 50", [U] DN1300 | 52", [U] DN1350 | 54", [V] DN1400 | 56", [W] DN1600 | 64", [X] DN1800 | 72", [Y] DN2000 | 80"
Nominal Pressure [A] 150 lb RF ASME B 16.5, [W] AWWA C207 Class D, [1] PN 6 EN 1092-1, [2] PN 10 EN 1092-1, [3] PN 16 EN 1092-1
Ex-Approval [0] without, [5] FM Class 1 Div 2, [A] cCSAus OL, [C] CSA Class 1 Div 2, [1] ATEX zone 1, [3] Ex zone 2, [F] IECEx zone 1
Design / Cable Connection [1] Compact Converter / at Converter, [2] Compact Stainless Steel Converter / at Converter, [3] Modular / without, [4] Remote Converter with Aluminum Junction Box / 1/2" NPT, [6] Remote Converter with Aluminum Junction Box / M20x1.5, [A] Remote Converter with Stainless Steel Junction Box / 1/2" NPT, [C] Remote Converter with Stainless Steel Junction Box / M20x1.5
Converter Model [3] IFC 100 C (Compact), [4] IFC 100 W (Wall Mount), [C] IFC 300 C (Compact), [D] IFC 300 F (Field Mount), [E] IFC 300 W (Wall Mount), [F] IFC 300 R (Rack Mount), [K] IFC 050 C (Compact), [L] IFC 050 W (Wall Mount), [M] IFC 400 C (Compact), [N] IFC 400 F (Field Mount), [0] without
Lining [0] Hardrubber, [7] Hardrubber H1005 - Certified for Potable Water
Electrodes [B] Hastelloy C22, [1] Stainless Steel 1.4571 | 316Ti, [3] Hastelloy C4, [6] Titanium
Housing / Flange Material [1] Sheet Steel / Carbon Steel, [3] Sheet Steel / 1.4404|316L Stainless Steel
Protection Class [0] IP66/67, [2] IP68 Factory, [1] IP68 Field
Cable [0] none - Compact Converter, [0] DS - Double Shielded, [1] BTS - Triple Shielded, [2] LIYCY, [4] DS Armoured, [Y] without
Cable Length [0] none - Compact Converter, [0] 5m | 15ft - Signal Cable, [1] 10m | 30ft - Signal Cable, [2] 15m | 45ft - Signal Cable, [3] 20m | 60ft - Signal Cable, [4] 25m | 75ft - Signal Cable, [5] 30m | 90ft - Signal Cable, [6] 40m | 120ft - Signal Cable, [7] 50m | 150ft - Signal Cable, [8] 100m | 300ft - Signal Cable, [0] 5m | 15ft - Signal Cable + Coil Cable, [1] 10m | 30ft - Signal Cable + Coil Cable, [2] 15m | 45ft - Signal Cable + Coil Cable, [3] 20m | 60ft - Signal Cable + Coil Cable, [4] 25m | 75ft - Signal Cable + Coil Cable, [5] 30m | 90ft - Signal Cable + Coil Cable, [6] 40m | 120ft - Signal Cable + Coil Cable, [7] 50m | 150ft - Signal Cable + Coil Cable, [8] 100m | 300ft - Signal Cable + Coil Cable, [Y] without
Calibration [0] 2-Point Calibration, [2] 2-Point Calibration + 316L SS Tagplate (120 x 46mm), [3] 2-Point Calibration + 316L SS Tagplate (67 x 25mm), [A] Custody Transfer, [C] Custody Transfer + 316L SS Tagplate (120 x 46mm), [D] Custody Transfer + 316L SS Tagplate (67 x 25mm), [H] 3 Points w/Water (Acc. to ISO/IEC 17025 2), [R] Extended Calibration, [S] Extended Calibration + 316L SS tagplate (120 x 46mm), [T] Extended Calibration + 316L SS tagplate (67 x 25mm)
Grounding Rings (x2) [0] without, [6] Grounding Ring #1 / Stainless Steel 1.4404|316L, [7] Grounding Ring #1 / Hastelloy C22, [5] Grounding Ring #1 / Titanium, [E] Insertion Ring #3 / Stainless Steel 1.4404|316L, [F] Insertion Ring #3 / Hastelloy C22, [D] Insertion Ring #3 / Titanium, [P] Protection Ring #2 / Stainless Steel 1.4404|316L, [R] Protection Ring #2 / Hastelloy C22, [N] Protection Ring #2 / Titanium
Finish [0] Standard, [3] Offshore
Markings [0] Krohne Blue, [H] Schneider Green
Extended Nominal Diameter [0] without, [7] DN +/+ 50|2", [B] DN +/+ 100|4", [D] DN +/+ 150|6"
Construction of Electrodes [1] Fixed Mounting
Construction Requirements [0] Standard
QA/QC Requirements [0] Standard
Ratio of CT-Calibration [0] R=30
Instruction Language [0] English/German
Tag Plate [0] Standard
Destination [0] Standard
Flange Material [0] Standard
Reserve Option [0] Standard