EZS TYPE2 R TRIP 30mm X 1200mm, LS2TR30-1200Q8
LS2TR30-1200Q8 EZS TYPE2 R TRIP 30mm X 1200mm
Defined Area Height Range:> 950 - <= 1300 mm
Feature: Low Profile:No
Supply Current:90 mA max.
Min Operating Temperature:0 °C
Max Operating Temperature:55 °C
Measurement Minimum:0
Ingress Protection:IP65
Housing Material_:Aluminum
Operating Voltage:24 VDC +/- 20%
Physical Dimensions:25.4 x 31.8 mm
Vibration:10-55 Hz at 0.35 mm
SIL Rating:SIL2; CL2
Recovery Time:N/A
Feature: ESD Safe:No
Feature: Test Input:Yes
OSSD Rating:24 VDC @ 0.5 A each
Overall Length:1264 mm
System Type:Receiver
Operating Distance:0.2 - 15 m
Response Time:22 ms
Effective Aperture Angle:Type 2 Per IEC 61496-2
Feature: Reduced Resolution:No
Feature: End-to-End Sensing:Yes
Number of Pins (Receiver/Emitter):8
Feature: Fault Output:No
Defined Area Height:1200 mm
Feature: Auxiliary Output:No
Electrical Safety Class:III
Shock:10g at 16ms (6000 cycles)
Feature: Short Protection:Yes
External Monitoring Device:None
Feature: Fixed Blanking:No
Safety Level:Type 2
Feature: Integral Muting:No
Scan Code:None
Trip/Latch Output:Trip
Electrical Connector Type:M12
Country of Origin:CN
Housing Finish:Yellow Polyester
Max Operating Range:> 8 to <= 20 m
Finish Material:Yellow Polyester
Specifications
Defined Area Height Range | > 950 - <= 1300 mm |
Feature: Low Profile | No |
Supply Current | 90 mA max. |
Min Operating Temperature | 0 °C |
Max Operating Temperature | 55 °C |
Measurement Minimum | 0 |
Ingress Protection | IP65 |
Housing Material_ | Aluminum |
Operating Voltage | 24 VDC +/- 20% |
Physical Dimensions | 25.4 x 31.8 mm |
Vibration | 10-55 Hz at 0.35 mm |
SIL Rating | SIL2; CL2 |
Recovery Time | N/A |
Feature: ESD Safe | No |
Feature: Test Input | Yes |
OSSD Rating | 24 VDC @ 0.5 A each |
Overall Length | 1264 mm |
System Type | Receiver |
Operating Distance | 0.2 - 15 m |
Response Time | 22 ms |
Effective Aperture Angle | Type 2 Per IEC 61496-2 |
Feature: Reduced Resolution | No |
Feature: End-to-End Sensing | Yes |
Number of Pins (Receiver/Emitter) | 8 |
Feature: Fault Output | No |
Defined Area Height | 1200 mm |
Feature: Auxiliary Output | No |
Electrical Safety Class | III |
Shock | 10g at 16ms (6000 cycles) |
Feature: Short Protection | Yes |
External Monitoring Device | None |
Feature: Fixed Blanking | No |
Safety Level | Type 2 |
Feature: Integral Muting | No |
Scan Code | None |
Trip/Latch Output | Trip |
Electrical Connector Type | M12 |
Country of Origin | CN |
Housing Finish | Yellow Polyester |
Max Operating Range | > 8 to <= 20 m |
Finish Material | Yellow Polyester |